S beam load cell built for a variety of applications which include medical devices such as patient lifting systems and process weighing/general measurement uses for hopper and suspended tank weight measurement.Our compact S shaped load cell range is available in low and high capacity choices suitable for tight environments
Excitation | 5 to 10 Vdc (15 Vdc maximum) |
Output | 2.0 mV/V ±0.25% |
Linearity | 0.03% FS |
Hysteresis | 0.02% FS |
Repeatability | 0.01% FS |
Zero Balance | 1% FS |
Creep in 20 min | 0.03% FS |
Operating Temperature | -18 to 66°C (0 to 150°F) |
Compensated Temperature | -18 to 66°C (0 to 150°F) |
Zero | 0.0027% FS/°C |
Span | 0.0015% FS/°C |
Dynamic load | 70% |
Maximum Safe Load | 150% |
Ultimate load | 300% |
Fatigue life | >1million |
Deflection | 0.3typ |
Bridge Resistance Excitation | 380 Ω nominal |
Bridge Resistance Sense | 350 Ω nominal |
Construction | 17-4 PH stainless steel |
Cable | 3 m (10') 6-conductor shielded 22-gauge PVC |
Capacity | Model No. | DEFL | Load Button | Rod End | |
---|---|---|---|---|---|
kgf | lb | mm | Model No. | Model No. | |
12.5 | 28 | CAMSLC-12 | 0.3 | CAMSLB-M6 | CAMSRE-M6 |
25 | 55 | CAMSLC-25 | 0.2 | CAMSLB-M6 | CAMSRE-M6 |
50 | 110 | CAMSLC-50 | 0.21 | CAMSLB-M6 | CAMSRE-M6 |
75 | 166 | CAMSLC-75 | 0.19 | CAMSLB-M6 | CAMSRE-M6 |
100 | 221 | CAMSLC-100 | 0.22 | CAMSLB-M6 | CAMSRE-M6 |
150 | 331 | CAMSLC-150 | 0.19 | CAMSLB-M6 | CAMSRE-M6 |
250 | 552 | CAMSLC-250 | 0.22 | CAMSLB-M6 | CAMSRE-M6 |
375 | 828 | CAMSLC-375 | 0.29 | CAMSLB-M10 | CAMSRE-M10 |
500 | 1104 | CAMSLC-500 | 0.29 | CAMSLB-M10 | CAMSRE-M10 |
750 | 1656 | CAMSLC-750 | 0.19 | CAMSLB-M12 | CAMSRE-M12 |
1000 | 2208 | CAMSLC-1000 | 0.22 | CAMSLB-M12 | CAMSRE-M12 |
1500 | 3311 | CAMSLC-1500 | 0.25 | CAMSLB-M20 | CAMSRE-M20 |
2500 | 5519 | CAMSLC-2500 | 0.2 | CAMSLB-M20 | CAMSRE-M20 |
Copyright © 2024 For Camaero Pvt Ltd. All Rights Reserved.